i220/SA1M

i-series

Universally applicable with a sales success for over 15 years.

The i-series is a standard range and easier to maintain than customer tailored products.

Features

■Test range:
・Maximum acceleration: 127 g
・Maximum velocity: 87 in/s
・Maximum displacement: 2.0 inp-p
・Maximum loading mass: 440 lbs
■Patented upper (armature) support system PS Guide
Parallel Slope Guide is standard
■All models can be directly coupled to a climatic chamber.

Table Insert Pattern (Unit:mm)

Table Insert Pattern

Specifications

Ecology

  System Model i220/EM1AM
System
Specifications
Frequency Range (Hz) 0-3,300
Rated
Force
Sine (lbf) 1,800
Random (lbf rms) *1 1,800
Shock (lbf) 3,600
High Velocity Shock(lbf)*5 2,250
Maximum
Acc.
Sine (g) 127
Random (g rms) 89
Shock (g peak) 204
High Velocity Shock (g peak)*5 159
Maximum
Vel.
Sine (in/s) 87
Shock (in/s peak) 87
High Velocity Shock (in/s peak)*5 137
Maximum
Dsp.
Sine (inp-p) 2.0
High Velocity Shock (inp-p)*5 2.0
Maximum Travel (inp-p) 2.4
Maximum Load.(lbs) 440
Power Requirements (kVA) *2 16.4
Breaker Capacity (A)*3 30
Vibration
Generator
Model i220
Armature Mass (lbs) 14.1
Armature Diameter (φin) 7.5
Allowable Eccentric Moment (lbf・in) 2,600
Dimensions (in) WxHxD 40 × 36 × 22
Shaker Body Diameter (φin) 22
Mass (lbs) 1,984
Power
mplifier
Model EM1AM-i20
Maximum Output (kVA) 10
Amplifier Bay (s) 1
Dimensions (in) WxHxD 23 × 69 × 33
Mass (lbs) 728
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Air cooling
Blower Dimensions (in) W×H×D*4 20 × 45 × 25
Mass (lbs) 155
Wattage (kw) 1.5
Duct Hose Diameter (φ) 125
  • *1 Random force ratings are specified in accordance with ISO53 44 conditions. Please contact IMV or your local distributor with specific test requirements.
  • *2 Power supply: 3-phase 220/480 V, 60 Hz. A transformer is required for other supply voltages.
  • *3 Breaker capacity for 480 V
  • *4 Spec described above is in case of 60Hz. Dimension is changed in case of 50Hz.
  • *5 In case of high velocity option
  • * The specification shows the maximum system performance. For long-duration tests, de-rating by up to 70 % must be applied. Continuous use at maximum levels may cause failure.
  • * In the case of Random vibration test, please set the test definition of the peak value of acceleration waveform to be operated less than the maximum acceleration of Shock.
  • * Frequency range values vary according to sensor and vibration controller.
  • * Armature mass and acceleration may change when chamber is comibined.
  • * Mass and dimensions may change for CE-marked systems.