AMERICAS

PRODUCTS

Case Study

High-Excitation Force Water-Cooled Range

High Excitation Force Water Cooled Type K125/SA16M

K-series

High-excitation force and silent water-cooled system for improving your test environment

K-series, the high-excitation force water-cooled vibration-simulating test systems fully developed by IMV.
Advanced performance from the K-series will significantly improve your test environment.

IMV-SmartTM technology

■Silent system design
The water-cooling system produces neither the intake nor exhaust sounds that an air-cooling system does.
■Record of significant accomplishments
IMV has developed the most advanced water-cooled system.

Table Insert Pattern (Unit: inch)

Table Insert Pattern

Specifications

Ecology

Eco Specifications
  System Model K080/
EM10HAM*6
K125A/
EM18HAM*6
K125LS/
EM20HAM*6
K200/
EM24HAM*6
K350/
EM36HAM*6
  Data Sheet
System
Specifications
Frequency Range (Hz) 0-2,500 0-2,500 0-2,000 0-2,000 0-2,000
Rated
Force
Sine (lbf) 18,000 28,100 28,100 45,000 78,700
Random (lbf rms)*1 18,000 28,100 28,100 45,000 70,800
Shock (lbf) 36,000 56,200 56,200 90,000 157,300
Maximum
Acc.
Sine (g) 102 102 102 102 102
Random (g rms) 71 71 71 71 71
Shock (g peak) 204 204 204 204 204
Maximum
Vel.
Sine (in/s)*3 79 79 79 79 79
Shock (in/s peak) 79 79 79 94 138
Maximum
Dsp.
Sine (inp-p) 2.0 2.0 4.0 3.0 3.4
Maximum
Travel (inp-p)
2.3 2.4 5.2 3.4 3.7
Maximum Load (lbs) 2,200 4,400 4,400 4,400 6,615
Power Requirements (kVA)*2 100 170 190 300 325
Breaker Capacity (A)*4 150 250 300 500 630 (total)
Vibration
Generator
Model K080 K125A K125LS K200 K350
Armature Mass (lbs) 132 177 221 441 772
Armature Diameter (φin) 17.6 22 22 25.6 29.9
Allowable Eccentric
Moment (lbf・in)
13,700 21,700 21,700 43,400 43,400
Dimensions (in) W × H × D 63 × 48 × 41 70 × 54 × 51 78 × 61 × 54 97 × 75 × 69 118.9 × 90.8 × 81.9
Shaker Body Diameter (φin) 39 43 43 50 64.2
Mass (lbs) 11,025 15,435 17,640 35,280 81,575
Power
Amplifier
Model EM10HAM-
K80
EM18HAM-
K125A
EM20HAM-
K125LS
EM24HAM-
K200
EM36HAM-
K350
Maximum Output (kVA) 100 124 155 320 400
Amplifier Bay(s) 2 3 3 5 7
Dimensions (in) W × H × D 46 × 77 × 34 69 × 77 × 34 69 × 77 × 34 114 × 77 × 34 161 × 77 × 34
Mass (lbs) 3,310 5,730 7,275 11,020 12,015
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Shaker: Water Cooling/Amp: Air Cooling
Required Cooling
Water Flow Rate
(gal/min)
Δt = 5℃ 103*5 103*5 103*5 172*5 182*5
Δt = 10℃ 25*5 39*5 39*5 60*5 66*5
Heat
Exchanger
Dimensions (in)
W × H × D
23 × 67 × 34 23 × 67 × 34 23 × 67 × 34 41 × 75 × 32 47 × 77 × 55
Mass (lbs) 885 885 885 1,325 1,325
  • *1 Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements.
  • *2 Power supply: 3-phase 220/480 V, 60 Hz. A transformer is required for other supply voltages.
  • *3 If the tests (Sweep or Spot) include high velocity, the maximum velocity value should be reduced to 5.5 in/s.
  • *4 Breaker capacity for 480 V.
  • *5 Bypass circuit is needed. Please contact IMV or your local distributor for further information.
  • *6 An export license is required for exporting a shaker system of over 11,240 lbf sine force.
  • * For random vibration tests, please set the test definition of the peak value of acceleration waveform to operate at less than the maximum acceleration of shock.
  • * Frequency range values vary according to sensor and vibration controller.
  • * Armature mass and acceleration may change when a chamber is added.
  • * Mass and dimensions may change for CE-marked systems.