AMERICAS

PRODUCTS

Case Study

High Excitation Force Water Cooled Range

High Excitation Force Water Cooled Type K125/SA16M

K-series

High excitation force and silent water cooled system for improving test environment

K-series, high excitation force water cooled vibration simulating test systems fully developed by IMV.
Advanced performance from the K-series will significantly improve the test environment.

Features

■Silent system design
The water cooling system produces neither the intake nor exhaust sounds that an air cooling system emits.
■Record of significant accomplishments
IMV has been developing the most advanced water cooled system.

Table Insert Pattern (Unit:mm)

Table Insert Pattern

Specifications

Ecology

Eco Specifications
  System Model K030/
EM4AM
K062/
EM8AM*6
K080/
EM10HAM*6
K125A/
EM14HAM*6
K125A/
EM18HAM*6
System
Specifications
Frequency Range(Hz) 0-3,000 0-2,500 0-2,500 0-2,500 0-2,500
Rated
Force
Sine(lbf) 6,900 13,900 18,000 22,500 28,100
Random
(lbf rms) *1
4,800 13,900 18,000 22,500 28,100
Shock(lbf) 13,800 27,800 36,000 45,000 56,200
Maximum
Acc.
Sine(g) 102 102 102 102 102
Random
(g rms)
57 71 71 71 71
Shock
(g peak)
204 204 204 204 204
Maximum
Vel.
Sine(in/s)*3 71 79 79 79 79
Shock
(in/s peak)
71 79 79 79 79
Maximum
Dsp.
Sine(inp-p) 2.0 2.0 2.0 2.0 2.0
Maximum
Travel(inp-p)
2.3 2.4 2.3 2.4 2.4
Maximum Load(lbs) 1,100 2,200 2,200 4,400 4,400
Power Requirements
(kVA) *2
49 87 100 150 170
Breaker Capacity
(A) *4
75 150 150 225 250
Vibration
Generator
Model K030 K060 K080 K125A K125A
Armature Mass(lbs) 60 88 132 177 177
Armature Diameter(φin) 12.6 15.7 17.6 22 22
Allowable Eccentric
Moment(lbf・in)
8,700 8,700 13,700 21,700 21,700
Dimensions(in)
WxHxD
44
×
43
×
33
55
×
43
×
40
63
×
48
×
41
70
×
54
×
51
70
×
54
×
51
Shaker Body Diameter
(φin)
30 35 39 43 43
Mass(lbs) 6,615 8,160 11,025 15,435 15,435
Power
Amplifier
Model EM4AM-
K30
EM8AM-
K60
EM10HAM-
K80
EM14HAM-
K125A
EM18HAM-
K125A
Maximum Output(kVA) 33 60 100 98 124
Amplifier Bay 2 2 2 3 3
Dimensions(in)
W×H×D
46
×
77
×
34
46
×
77
×
34
46
×
77
×
34
69
×
77
×
34
69
×
77
×
34
Mass(lbs) 2,870 2,980 3,310 5,510 5,730
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Shaker:Water Cooling/Amp:Air Cooling
Required Cooling
Water Flow Rate
(gal/min)
Δt = 5℃ 52 69 103 103 103
Δt = 10℃ 10 20 25 25 39
Heat
Exchanger
Dimensions(in)
W×H×D
23
×
67
×
34
23
×
67
×
34
23
×
67
×
34
23
×
67
×
34
23
×
67
×
34
Mass(lbs) 885 885 885 885 885
  System Model K125LS/
EM16HAM*6
K125LS/
EM20HAM*6
K200/
EM20HAM*6
K200/
EM24HAM*6
K350/
EM36HAM*6
System
Specifications
Frequency Range(Hz) 0-2,000 0-2,000 0-2,000 0-2,000 0-2,000
Rated
Force
Sine(lbf) 22,500 28,100 36,000 45,000 78,700
Random
(lbf rms) *1
22,500 28,100 36,000 45,000 70,800
Shock(lbf) 45,000 56,200 72,000 90,000 157,300
Maximum
Acc.
Sine(g) 102 102 82 102 102
Random
(g rms)
71 71 57 71 71
Shock
(g peak)
204 204 163 204 204
Maximum
Vel.
Sine(in/s)*3 79 79 79 79 79
Shock
(in/s peak)
79 79 94 94 138
Maximum
Dsp.
Sine(inp-p) 4.0 4.0 3.0 3.0 3.4
Maximum
Travel(inp-p)
5.2 5.2 3.4 3.4 3.7
Maximum Load(lbs) 4,400 4,400 4,400 4,400 6,615
Power Requirements
(kVA) *2
170 190 270 300 325
Breaker Capacity
(A) *4
250 300 400 500 630
(total)
Vibration
Generator
Model K125LS K125LS K200 K200 K350
Armature Mass(lbs) 221 221 441 441 772
Armature Diameter(φin) 22 22 25.6 25.6 29.9
Allowable Eccentric
Moment(lbf・in)
21,700 21,700 43,400 43,400 43,400
Dimensions(in)
WxHxD
78
×
61
×
54
78
×
61
×
54
97
×
75
×
69
97
×
75
×
69
118.9
×
90.8
×
81.9
Shaker Body Diameter
(φin)
43 43 50 50 64.2
Mass(lbs) 17,640 17,640 35,280 35,280 81,575
Power
Amplifier
Model EM16HAM-
K125LS
EM20HAM-
K125LS
EM20HAM-
K200
EM24HAM-
K200
EM36HAM-
K350
Maximum Output(kVA) 124 155 256 320 400
Amplifier Bay 3 3 5 5 7
Dimensions(in)
WxHxD
69
×
77
×
34
69
×
77
×
34
114
×
77
×
34
114
×
77
×
34
161
×
77
×
34
Mass(lbs) 5,730 7,275 10,690 11,020 12,015
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Shaker:Water Cooling/Amp:Air Cooling
Required Cooling
Water Flow Rate
(gal/min)
Δt = 5℃ 103 103 172*5 172*5 182*5
Δt = 10℃ 39 39 60*5 60*5 66*5
Heat
Exchanger
Dimensions(in)
WxHxD
23
×
67
×
34
23
×
67
×
34
41
×
75
×
32
41
×
75
×
32
47
×
77
×
55
Mass(lbs) 885 885 1,325 1,325 1,325
  • *1 Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements.
  • *2 Power supply: 3-phase 220 / 480 V, 60 Hz. A transformer is required for other supply voltages.
  • *3 If the tests (Sweep or Spot) include high velocity, the maximum velocity value should be reduced to 5.5 in/s.
  • *4 Breaker capacity for 480 V.
  • *5 Bypass circuit is needed. Please contact IMV or your local distributor for further information.
  • *6 E/L is required for exporting the shaker system of over 11,240 lbf Sine force.
  • * The specification shows the maximum system performance. For long-duration tests, de-rating by up to 70 % must be applied. Continuous use at maximum levels may cause failure. Please contact IMV if you use more than 70 %.
  • * In the case of Random vibration test, please set the test definition of the peak value of acceleration waveform to be operated less than the maximum acceleration of Shock.
  • * Frequency range values vary according to sensor and vibration controller.
  • * Armature mass and acceleration may change when chamber is comibined.
  • * Mass and dimensions may change for CE-marked systems.